October 18, 2022 – Tuesday
XRF Test Results for the Pumpkin Votive Holder Pictured
Reading #1) on the orange glaze
60-second reading
- Lead (Pb): 550 +/- 39 ppm
- Cadmium (Cd): 644 +/- 30 ppm
- Tin (Sn): 35 +/- 14 ppm
- Mercury (Hg): non-detect
- Selenium (Se): non-detect
- Barium (Ba): 1,944 +/- 95 ppm
- Chromium (Cr): 973 +/- 402 ppm
- Antimony (Sb): non-detect
- Copper (Cu): 243 +/- 44 ppm
- Zinc (Zn): 13,600 +/- 400 ppm
- Manganese (Mn): 545 +/- 231 ppm
- Titanium (Ti): 9,537 +/- 1.990 ppm
- Zirconium (Zr): 18,200 +/- 500 ppm
- Niobium (Nb): 206 +/- 24 ppm
- Indium (In): 21 +/- 11 ppm
- Iron (Fe): 1,416 +/- 181 ppm
- Vanadium (V): 3,159 +/- 1,060 ppm
- Platinum (Pt): 122 +/- 75 ppm
- Bismuth (Bi): 57 +/- 19 ppm
- No other metals detected in consumer goods mode.
Reading #2) on the brown glaze
60-second reading
- Lead (Pb): 581 +/- 35 ppm
- Cadmium (Cd): 26 +/- 6 ppm
- Tin (Sn): 30 +/- 10 ppm
- Mercury (Hg): non-detect
- Selenium (Se): non-detect
- Barium (Ba): 1,672 +/- 66 ppm
- Chromium (Cr): 2,060 +/- 412 ppm
- Antimony (Sb): non-detect
- Copper (Cu): 64 +/- 31 ppm
- Zinc (Zn): 11,900 +/- 300 ppm
- Manganese (Mn): non-detect
- Titanium (Ti): 10,100 +/- 1.900 ppm
- Zirconium (Zr): 296 +/- 14 ppm
- Niobium (Nb): 234 +/- 20 ppm
- Indium (In): non-detect
- Iron (Fe): 4,206 +/- 249 ppm
- Vanadium (V): 2,435 +/- 1,006 ppm
- Platinum (Pt): non-detect
- Bismuth (Bi): 114 +/- 18 ppm
- No other metals detected in consumer goods mode.
Reading #3) on the white glaze / bottom with sticker
60-second reading
- Lead (Pb): 214 +/- 17 ppm
- Cadmium (Cd): 13 +/- 4 ppm
- Tin (Sn): 31 +/- 7 ppm
- Mercury (Hg): non-detect
- Selenium (Se): non-detect
- Barium (Ba): 161 +/- 27 ppm
- Chromium (Cr): non-detect
- Antimony (Sb): non-detect
- Copper (Cu): 31 +/- 20 ppm
- Zinc (Zn): 111 +/- 17 ppm
- Manganese (Mn): non-detect
- Titanium (Ti): non-detect
- Zirconium (Zr): non-detect
- Niobium (Nb): 308 +/- 16 ppm
- Indium (In): 18 +/- 6 ppm
- Iron (Fe): 2,946 +/- 173 ppm
- Vanadium (V): non-detect
- Platinum (Pt): 43 +/- 27 ppm
- Bismuth (Bi): 141 +/- 12 ppm
- No other metals detected in consumer goods mode.
For those new to this website
Tamara Rubin is a Federal-award-winning independent advocate for consumer goods safety and a documentary filmmaker. She is also a mother of Lead-poisoned children. Tamara’s sons were acutely Lead-poisoned in August of 2005. She began testing consumer goods for toxicants in 2009 and was the parent-advocate responsible for finding Lead in the popular fidget spinner toys in 2017. Her work was also responsible for two CPSC product recalls in the summer of 2022, the Jumping Jumperoo recall (June 2022) and the Lead painted NUK baby bottle recall (July 2022) and was featured in an NPR story about Lead in consumer goods in August of 2022. Tamara uses XRF testing (a scientific method used by the U.S. Consumer Product Safety Commission) to test consumer goods for toxicants (specifically heavy metals), including Lead, Cadmium, Mercury, Antimony, and Arsenic. All test results reported on this website are science-based, accurate, and replicable. Items are tested multiple times, to confirm the test results for each component tested and reported on. Please click through to this link to learn more about the testing methodology used for the test results discussed and reported on this website.