SIDINIC hearing protectors, black and green: 412 ppm Lead + 46 ppm Cadmium in the headband vinyl
Sidinic hearing protectors
For those new to this website:
Tamara Rubin is a multiple-federal-award-winning independent advocate for childhood Lead poisoning prevention and consumer goods safety, and a documentary filmmaker. She is also a mother of Lead-poisoned children (two of her sons were acutely Lead-poisoned in 2005). Since 2009, Tamara has been using XRF technology (a scientific method used by the U.S. Consumer Product Safety Commission) to test consumer goods for toxicants (specifically heavy metals — including Lead, Cadmium, Mercury, Antimony, and Arsenic). All test results reported on this website are science-based, accurate, and replicable. Items are tested multiple times to confirm the test results for each component tested. Tamara’s work was featured in Consumer Reports Magazine in February of 2023 (March 2023 print edition).
Reading #1) Green hard plastic outside of ear case
30-second reading
- Lead (Pb): non-detect
- Arsenic (As): non-detect
- Cadmium (Cd): non-detect
- Mercury (Hg): non-detect
- Bromine (Br): non-detect
- Chromium (Cr): non-detect
- Iron (Fe): 26 +/- 11 ppm
- Titanium (Ti): 257 +/- 118 ppm
- Barium (Ba): 145 +/- 53 ppm
- No other metals were detected in consumer goods mode.
Reading #2) Vinyl top of head strap
30-second reading
- Lead (Pb): 412 +/- 27 ppm
- Arsenic (As): non-detect
- Cadmium (Cd): 46 +/- 6 ppm
- Mercury (Hg): non-detect
- Bromine (Br): 15 +/- 4 ppm
- Chromium (Cr): non-detect
- Iron (Fe): 3,529 +/- 218 ppm
- Cobalt (Co): 118 +/- 70 ppm
- Copper (Cu): 74 +/- 34 ppm
- Zinc (Zn): 474 +/- 38 ppm
- Manganese (Mn): 1,115 +/- 207 ppm
- Zirconium (Zr): 207 +/- 11 ppm
- Niobium (Nb): 1,137 +/- 33 ppm
- Molybdenum (Mo): 843 +/- 34 ppm
- Indium (In): 18 +/- 7 ppm
- Tin (Sn): 82 +/- 9 ppm
- Antimony (Sb): 54 +/- 13 ppm
- Tungsten (W): 113 +/- 75 ppm
- No other metals were detected in consumer goods mode.
Reading #3) Underside vinyl/ fabric/ foam of head strap
30-second reading
- Lead (Pb): non-detect
- Arsenic (As): non-detect
- Cadmium (Cd): 22 +/- 9 ppm
- Mercury (Hg): non-detect
- Bromine (Br): 28 +/- 7 ppm
- Chromium (Cr): 280 +/- 84 ppm
- Iron (Fe): 503,900 +/- 11,000 ppm
- Cobalt (Co): 4,392 +/- 392 ppm
- Copper (Cu): 322 +/- 60 ppm
- Zinc (Zn): 1,043 +/- 76 ppm
- Manganese (Mn): 3,203 +/- 184 ppm
- Niobium (Nb): 1,617 +/- 62 ppm
- Molybdenum (Mo): 1,012 +/- 57 ppm
- Titanium (Ti): 1,582 +/- 277 ppm
- Indium (In): 21 +/- 11 ppm
- Tin (Sn): 214 +/- 18 ppm
- Antimony (Sb): 39 +/- 20 ppm
- Tungsten (W): 212 +/- 125 ppm
- Platinum (Pt): 271 +/- 76 ppm
- No other metals were detected in consumer goods mode.
Reading #4) Vinyl-encased foam edging around ears
30-second reading
- Lead (Pb): non-detect
- Arsenic (As): non-detect
- Cadmium (Cd): non-detect
- Mercury (Hg): non-detect
- Bromine (Br): non-detect
- Chromium (Cr): non-detect
- Iron (Fe): 122 +/- 34 ppm
- Zinc (Zn): 133 +/- 12 ppm
- Tin (Sn): 106 +/- 6 ppm
- Barium (Ba): 119 +/- 20 ppm
- No other metals were detected in consumer goods mode.
Reading #5) Foam insert inside ear-cups
30-second reading
- Lead (Pb): non-detect
- Arsenic (As): non-detect
- Cadmium (Cd): non-detect
- Mercury (Hg): non-detect
- Bromine (Br): non-detect
- Chromium (Cr): non-detect
- Iron (Fe): 75 +/- 24 ppm
- Tin (Sn): 411 +/- 22 ppm
- Barium (Ba): 237 +/- 100 ppm
- No other metals were detected in consumer goods mode.