Reading #1) on the red plastic hat
60-second reading
- Lead (Pb): non-detect
- Cadmium (Cd): 836 +/- 10 ppm
- Arsenic (As): non-detect
- Mercury (Hg): non-detect
- Bromine (Br): non-detect
- Chromium (Cr): 202 +/- 79 ppm
- Iron (Fe): 78 +/- 42 ppm
- Copper (Cu): 27 +/- 17 ppm
- Zinc (Zn): 1,012 +/- 26 ppm
- Barium (Ba): 2,253 +/- 37 ppm
- Chlorine (Cl): 360,000 ppm
- No other metals detect in consumer goods mode.
Reading #2) on the brown fur
60-second reading
- Lead (Pb): non-detect
- Cadmium (Cd): non-detect
- Arsenic (As): non-detect
- Mercury (Hg): non-detect
- Bromine (Br): non-detect
- Chromium (Cr): 52 +/- 29 ppm
- Iron (Fe): 95 +/- 19 ppm
- Zinc (Zn): 18 +/- 5 ppm
- Tin (Sn): 15 +/- 3 ppm
- Barium (Ba): 38 +/- 11 ppm
- Chlorine (Cl): 360,000 ppm
- No other metals detect in consumer goods mode.
Reading #3) on the black eyeballs
60-second reading
- Lead (Pb): non-detect
- Cadmium (Cd): non-detect
- Arsenic (As): non-detect
- Mercury (Hg): non-detect
- Bromine (Br): 2 +/- 1 ppm
- Chromium (Cr): 76 +/- 14 ppm
- Iron (Fe): 434 +/- 11 ppm
- Nickel (Ni): 7 +/- 3 ppm
- Zinc (Zn): 2,733 +/- 15 ppm
- Barium (Ba): 244 +/- 29 ppm
- Gold (Au): 58 +/- 6 ppm
- No other metals detect in consumer goods mode.
Reading #4) on the brown plastic feet
60-second reading
- Lead (Pb): non-detect
- Cadmium (Cd): 18 +/- 2 ppm
- Arsenic (As): non-detect
- Mercury (Hg): non-detect
- Bromine (Br): non-detect
- Chromium (Cr): non-detect
- Iron (Fe): 8,987 +/- 162 ppm
- Zinc (Zn): 1,898 +/- 38 ppm
- Niobium (Nb): 696 +/- 12 ppm
- Indium (In): 17 +/- 3 ppm
- Tin (Sn): 15 +/- 4 ppm
- Antimony (Sb): 21 +/- 6 ppm
- No other metals detect in consumer goods mode.
Reading #5) on the blue fabric
60-second reading
- Lead (Pb): non-detect
- Cadmium (Cd): non-detect
- Arsenic (As): non-detect
- Mercury (Hg): non-detect
- Bromine (Br): non-detect
- Chromium (Cr): 34 +/- 19 ppm
- Iron (Fe): 81 +/- 9 ppm
- Copper (Cu): 29 +/- 5 ppm
- Zinc (Zn): 32 +/- 3 ppm
- Titanium (Ti): 1,070 +/- 98 ppm
- Antimony (Sb): 13 +/- 8 ppm
- Barium (Ba): 156 +/- 39 ppm
- No other metals detect in consumer goods mode.
Reading #6) on the brown plastic of hands
60-second reading
- Lead (Pb): 5 +/- 3 ppm
- Cadmium (Cd): 61 +/- 3 ppm
- Arsenic (As): non-detect
- Mercury (Hg): non-detect
- Bromine (Br): non-detect
- Chromium (Cr): non-detect
- Iron (Fe): 246 +/- 28 ppm
- Zinc (Zn): 253 +/- 11 ppm
- Tin (Sn): 459 +/- 7 ppm
- Barium (Ba): 284 +/- 17 ppm
- Chlorine (Cl): 360,000 ppm
- No other metals detect in consumer goods mode.
For those new to this website:
Tamara Rubin is a Federal-award-winning independent advocate for consumer goods safety and a documentary filmmaker. She is also a mother of Lead-poisoned children. Tamara’s sons were acutely Lead-poisoned in August of 2005. She began testing consumer goods for toxicants in 2009 and was the parent-advocate responsible for finding Lead in the popular fidget spinner toys in 2017. Tamara uses XRF testing (a scientific method used by the U.S. Consumer Product Safety Commission) to test consumer goods for toxicants (specifically heavy metals), including Lead, Cadmium, Mercury, Antimony, and Arsenic. All test results reported on this website are science-based, accurate, and replicable. Items are tested multiple times, to confirm the test results for each component tested. Please click through to this link to learn more about the testing methodology used for the test results discussed and reported on this website.
Leave a Reply