Tamara Rubin is a Federal award winning independent advocate for consumer goods safety and childhood Lead poisoning prevention. She is also a mother of Lead-poisoned children. She began testing consumer goods for toxicants in 2009, and was the parent-advocate responsible for finding Lead in the popular fidget spinner toys in 2017. She uses XRF testing (a scientific method used by the Consumer Product Safety Commission) to test consumer goods for metallic toxicants (including Lead, Cadmium, Mercury and Arsenic). To read more about the testing methodology employed for the test results reported on this blog, please click this link.


These posts today are placeholders JUST with the XRF data for the item pictured. They will be updated with more details a.s.a.p. All readings are done multiple times to confirm the results for each component before sharing one full set of the readings for the item pictured.

#1) Floral design component of the rim of the food surface of the dish
60-second reading

  • Lead (Pb): 12,300 +/- 100 ppm
  • Cadmium (Cd): non-detect
  • Mercury (Hg): 14 +/- 7 ppm
  • Bromium (Br): non-detect
  • Chromium (Cr): non-detect
  • Iron (Fe): 3,732 +/- 86 ppm
  • Zinc (Zn): 1,562 +/- 28 ppm
  • Indium (In): 7 +/- 3 ppm
  • Tin (Sn): 67 +/- 4 ppm
  • Antimony (Sb): 115 +/- 6 ppm
  • Platinum (Pt): 237 +/- 27 ppm
  • no other metals detected

#2) Cream colored component of the rim of the food surface of the dish
60-second reading

  • Lead (Pb): 5,395 +/- 57 ppm
  • Cadmium (Cd): 4 +/- 2 ppm
  • Mercury (Hg): non-detect
  • Bromium (Br): non-detect
  • Chromium (Cr): non-detect
  • Iron (Fe): 3,630 +/- 89 ppm
  • Zinc (Zn): 536 +/- 16 ppm
  • Indium (In): 7 +/- 3 ppm
  • Tin (Sn): 12 +/- 3 ppm
  • Antimony (Sb): 24 +/- 5 ppm
  • Platinum (Pt): 136 +/- 21 ppm
  • no other metals detected

#3) White center of food surface of dish
60-second reading

  • Lead (Pb): 56 +/- 4 ppm
  • Cadmium (Cd): 6 +/- 2 ppm
  • Mercury (Hg): non-detect
  • Bromium (Br): non-detect
  • Chromium (Cr): non-detect
  • Iron (Fe): 3,014 +/- 79 ppm
  • Zinc (Zn): 99 +/- 7 ppm
  • Indium (In): 6 +/- 3 ppm
  • Tin (Sn): 10 +/- 3 ppm
  • Bismuth (Bi): 36 +/- 4 ppm
  • no other metals detected

Some additional reading that may be of interest:

As always, please let me know if you have any questions. Thank you for reading and thank you for sharing my posts.

Tamara Rubin
#LeadSafeMama

shop lead free banner

Never Miss an Important Article Again!

Join our Email List

Leave a Reply

Your email address will not be published. Required fields are marked *